Portable Mobile Laboratory: Six Sizes, 100 to 400 sq ft

Choose your size - six approved laboratory sizes

20×10 ft Portable Mobile Laboratory

₹4,00,000 + GST

₹4,72,000 incl. 18% GST

A portable mobile laboratory is a factory-built steel room finished as a laboratory before it leaves the works, not an office cabin with a table in it. This page carries SAMAN's six approved sizes, 100 to 400 sq ft, every one 8.5 ft high on 100 mm walls, with a coved vinyl floor, a washable wall liner and a fixed bench and sink schedule taken from its approved GA drawing. Each size publishes its clear cleaning aisle, so you know before you order whether a trolley and a technician pass each other. Prices are ex-GST for the lab-ready enclosure and its scheduled fixed provisions. Instruments, fume hoods, gases, RO or DI water, validation and accreditation are excluded. Built in Bengaluru and Greater Noida.

Size
20×10×8.5 ft · 200 sq ft
Roof
Two-way, centred ridge
Openings
1 door · 6 windows
Benching
3 bench runs · 1 sink · 4 upper modules
Cleaning aisle
≈ 5.34 ft clear
Material
MS frame · corrugated MS shell
Delivery
7–21 Working Days
Coverage
Bangalore · Delhi NCR
Brand
SAMAN Portable

Custom sizes available · 500+ projects delivered · Factory-tested before dispatch

Product Information

Download technical specification (PDF)

GST registered

Portable Mobile Laboratory: A Cleanable Room, Not an Office Cabin

Use this page when the room itself has to be cleanable. A portable mobile laboratory is built on the same steel platform as the Portable Office Cabin range, and then finished differently: a coved vinyl floor with no square corner to trap spill, a washable wall liner with cleanable junctions, a non-absorbent bench substrate, and one sealed utility sleeve that is frozen on the drawing before any penetration is cut. That finish, not the furniture, is what you are buying.

Every size here is an open lab room with no partitions, because a partition in a 10 ft width creates a corner nobody can reach with a mop. The bench runs, the single sink or service interface and the upper storage modules are scheduled in feet on the GA drawing, and the end walls stay furniture-free with one centred window each. What is excluded is listed on this page, not discovered at handover.

Send your size for a fixed quote
Inside the 20x10 ft portable mobile laboratory: the sample intake and equipment allowance benches on one wall, the continuous workbench and sink opposite, and the clear cleaning aisle between them

One sink, one sealed sleeve, and a cleaning aisle you can measure

Every size follows the same arrangement: a sample intake bench, an equipment allowance bench, a continuous workbench opposite, and one sink at a coordinate scheduled in feet on the approved drawing.

Between the benches sits the clear cleaning aisle, scheduled for every size: 5.34 ft on most, 7.34 ft on the 10×10 and the 20×12. That figure, not the floor area, decides whether a trolley passes a working technician.

Compare the six sizes

Compare the six laboratory sizes, 100 to 400 sq ft

Six approved sizes, one lab-ready finish, one price rule. Each size shows the unit, its bench and sink schedule and its cleaning aisle.

20x10 ft portable mobile laboratory in pearl off-white: window, door and window on Wall A, the reference size for the price rule

20×10 ft Portable Mobile Laboratory: 200 sq ft, Three Benches

This is the reference size for the price rule: ₹2,000 per sq ft at 200 sq ft is the base from which every other size on this page is adjusted. It is also the first size that splits the work. Wall A carries a 7 ft sample intake bench and a separate 7 ft equipment allowance bench with the door between them; Wall B carries a continuous 18.5 ft workbench with the sink at its far end. Samples land on one side, work happens on the other.

  • 20×10×8.5 ft, 200 sq ft, ₹4,00,000 ex-GST (₹4,72,000 incl. 18% GST)
  • Base rate size: ₹2,000/sq ft, no area-band adjustment
  • 3 fixed bench runs, 1 sink at 16.75–18.25 ft, 4 upper storage modules
  • 7 ft sample intake bench and 7 ft equipment allowance bench, separated by the door on Wall A
  • Clear cleaning aisle ≈ 5.34 ft between the Wall A and Wall B bench faces
  • Two-way roof, centred ridge along the 20 ft length
20×10×8.5 ft200 sq ft₹4,00,000 + GST2,000/sq ft

20×10 ft Portable Mobile Laboratory

₹4,00,000 + GST

SAMAN portable cabin calculator
SAMAN Portable

PRICE IT YOURSELF

Your Portable Mobile Laboratory from ₹2,30,000

Set the size, choose the finish, watch the price move as you go.

Start your design

Custom quote target: 48 business hours. Built in our own works.

Customized cabin

Portable Mobile Laboratory

20×10 ft · 200 sq ft

Estimated total

₹2,10,980₹2,48,956 incl. GST

Step 1 of 9

Choose your product

Pick the building closest to what you need. You can change it at any point.

Choose your product

Set the size

Area and price update as you type. Every size prices from our base-cabin rate card; the larger the floor area, the lower the rate per square foot.

Enter a length and width between 4 and 60 ft. For larger buildings, request a quotation and we will size it with you.

Rooms and partitions
Partition doors
Drawing view
D1W1W220' 0"10' 0"2D Plan

R = room · D = door · W = window

On the drawing, R1 is Room 1, D1 is Door 1 and W1 is Window 1. Every control and every line of your quotation uses the full words.

Carpet Area200 sq ft
Base cabin price₹2,00,000
Roof
Mobility

Enter any size you need. All sizes price from the same base-cabin rate card, and your figure is confirmed on the drawing.

Frame and wall

Choose what the cabin is built from. The frame carries the load, the wall closes it, and both move the price.

Structural frame
Wall construction

Choose the interior

Standard finishes are included. Upgrades and savings are shown per square foot.

Internal wall lining, per sq ft of wall
Ceiling, per sq ft of floor
Flooring, per sq ft of floor
Wall build-up from outside to inside
Weather skin50
Structural faceMS frame & panel support
Thermal layer50 PUF
Added insulation, per sq ft of wall and ceiling

Add doors and windows

Set the type, the count and where each one sits. The plan updates as you choose.

Door placement

Door 1
Hinge side
Opening
Use "In" when hand flow should remain inside the room edge. Use "Out" when swing clearance is outside.

Window placement

Window 1
Track
Track choice affects how much frame is needed along the edge.
Window 2
Track
Track choice affects how much frame is needed along the edge.

If the entrance sits under a shed or a covered walkway, choose opens in, so rain does not blow through the doorway. On an open site choose opens out, because the door seals tighter against wind. Hinge left and hinge right set which side the handle falls on.

A 2.5 track slides more smoothly and costs more than a 2 track. The difference scales with the size of the window.

Drawing view
D1W1W220' 0"10' 0"2D Plan

R = room · D = door · W = window

On the drawing, R1 is Room 1, D1 is Door 1 and W1 is Window 1. Every control and every line of your quotation uses the full words.

Carpet Area200 sq ft
Base cabin price₹2,00,000

Add electrical fittings

Tick what you need. Quantities are suggested from the floor area and you can change every one.

Light colour
LED shape
Socket placement, no cost impact

Placement moves a socket, it does not add one. The charge is the plug point count above, and moving a socket costs nothing.

Front
Rear
Left
Right
Drawing view
D1W1W220' 0"10' 0"2D Plan

R = room · D = door · W = window

On the drawing, R1 is Room 1, D1 is Door 1 and W1 is Window 1. Every control and every line of your quotation uses the full words.

Carpet Area200 sq ft
Base cabin price₹2,00,000

Add furniture and fittings

Everything here is optional. Add only what you want fitted before delivery.

Some fit-out components are being confirmed and show as Quoted separately.

Furniture position

Delivery and taxes

Transport and installation are optional and depend on your site. GST is shown as its own line.

Delivery scope
See the full distance ladder
Delivery freight ladder, ex-GST. Freight figures are tentative and confirmed with the delivery quotation.
Distance20 ft trailer40 ft trailer
Bangalore cityFreeFree
Delhi NCRFreeFree
Under 100 kmConfirmed at quotationConfirmed at quotation
100-150 km₹27,500₹32,500
150-200 km₹32,500₹37,500
200-250 km₹37,500₹42,500
250-300 km₹42,500₹47,500
300-350 km₹47,500₹52,500
350-400 km₹52,500₹57,500
400-450 km₹57,500₹62,500
450-500 km₹62,500₹67,500
500-550 km₹67,500₹72,500
550-600 km₹72,500₹77,500
600-650 km₹77,500₹82,500
650-700 km₹82,500₹87,500
700-750 km₹87,500₹92,500
750-800 km₹92,500₹97,500
800-850 km₹97,500₹1,02,500
850-900 km₹1,02,500₹1,12,500
900-950 km₹1,07,500₹1,17,500
950-1000 km₹1,12,500₹1,22,500

Delivery in 7 to 21 working days. Freight is confirmed once the exact delivery location and order are approved.

Get your quotation

We aim to send your fixed-price quotation within 48 business hours after receiving complete dimensions, specifications, delivery PIN code and scope. Complex engineered configurations may require additional time, which we will confirm.

Submit the exact configuration for an itemised quotation. Custom quote target: 48 business hours.

Your contact detailsEnter a 10-digit Indian mobile number.Please add your email so we can send your quotation PDF.

Please add your name and mobile number so our sales team can send your fixed quotation.

Published cabin price tables

All primary prices are ex-GST. Including-GST figures apply 18 percent GST.

Portable Office price table
Portable Office published size and price ladder
SizeAreaPrice ex-GSTIncluding 18% GST
10×10 ft100 sq ft₹2,30,000₹2,71,400
20×8 ft160 sq ft₹3,52,000₹4,15,360
20×10 ft200 sq ft₹4,00,000₹4,72,000
20×12 ft240 sq ft₹4,60,800₹5,43,744
30×10 ft300 sq ft₹5,76,000₹6,79,680
40×10 ft400 sq ft₹7,60,000₹8,96,800
Indicative estimate SP-EST · 10 Sept 2026 · Custom quote target: 48 business hours after submission.

You may also like

More portable office configurations on the same steel cabin platform.

Product Details

Comprehensive information about Portable Mobile Laboratory

Product Overview

Detailed information about Portable Mobile Laboratory

Portable mobile laboratory, or a laboratory on wheels? Read this first

Search for a mobile laboratory in India and most of what comes back is a vehicle. A lab built into a truck body, a diagnostic unit on a motorbike, a science van that visits schools. Those are real products and they solve a real problem, which is testing that has to move from place to place during the working week. This page is about the other thing that shares the name.

A SAMAN portable mobile laboratory is a factory-built steel room. It is finished as a laboratory in the works, loaded onto a trailer, lifted off by its four top-corner eyes and set down on prepared supports. It is portable in the sense that it can be moved when the project moves, or relocated between plants, not in the sense that it drives to a sampling point and comes back. If your testing has to happen at a different address every day, a vehicle is the right answer and nothing here will help you.

Inside a 20x10 ft portable mobile laboratory: benches on both long walls, a continuous workbench and a clear cleaning aisle, showing that this is a placed room and not a vehicle

If instead your testing happens in one place for months or years, and that place has no building fit to hold it, a placed laboratory is usually the cheaper and more workable answer. It gives you a full 8.5 ft standing height, benching along the walls at working depth, mains power through a proper distribution board, and a floor and wall finish designed to be washed. A vehicle body gives you none of those at the same cost.

The word cabin also appears on other parts of this site and it is worth separating them now. A container office is built from or like an ISO shipping container and belongs on the Container Offices pages. An office cabin is a dry office interior with desks, and belongs on the Portable Office pages. The laboratory sits apart from both, because the thing that defines it is not its shape but its finish: the room is built to be cleaned.

Who orders a portable mobile laboratory, and where it stands

The enquiries that end in an order share one shape. There is a process running at a fixed location, that process produces samples, and the samples currently travel somewhere else to be tested. Every hour of that travel is an hour the plant runs on an assumption. The buyer wants the test next to the process.

Sample flow in a 30x10 ft portable mobile laboratory: a short intake bench on Wall A between the two external doors and a 28.5 ft workbench opposite

In practice that means a quality control room at a ready-mix or aggregate plant, taking cube and slump samples off the batching line. A soil and material testing room on a road or rail package, where the laboratory follows the works. A sample receiving and screening point at a food or agricultural processing unit. A works laboratory at a chemical or pharmaceutical site where an existing building has no spare room that can be brought to a cleanable standard. A metering and calibration room beside a utility installation.

The people using it are a lab technician, a sample handler, a quality engineer and, periodically, a maintenance engineer who needs to reach the services without dismantling the benching. The unit is normally placed in a testing compound or beside a sample receiving point, on a levelled base, with a wash-down approach and a utility trench or route already agreed. Where it stands is a decision that has to be made before the drawing is frozen, because the sealed service sleeve is cut on one wall at one coordinate, and that coordinate has to face the services.

What lab-ready means on this page, and what it does not

Lab-ready here means the enclosure and the fixed provisions scheduled on the approved GA drawing, and nothing beyond them. That is a deliberately narrow definition and it is the honest one, because the difference between a quoted laboratory enclosure and a working accredited laboratory can be several times the price of the room.

What the price on this page covers is the steel shell in one of the six approved sizes at 8.5 ft nominal height on 100 mm walls; the coved vinyl floor finish, which turns the floor-to-wall junction into a radius rather than a corner; the washable wall liner with cleanable junctions; the non-absorbent bench substrate; the fixed bench runs, the single sink or service interface and the upper storage modules exactly as the GA schedules them in feet; the door and window schedule with end walls kept furniture-free; the standard electrical package with distribution board, RCCB and MCB protection, earthing and circuit segregation; one sealed utility sleeve; and four compact top-corner lifting eyes.

Linear workflow in a 20x8 ft portable mobile laboratory: one continuous 18.5 ft bench running from the door end to the sink, with coved vinyl floor and washable liner

What it does not cover, and what is quoted separately or excluded outright:

  • Instruments and loose equipment of every kind. The balances, microscopes and analysers in the photographs are customer-supplied and are shown to give the benching scale.
  • Fume hoods and any process exhaust system. The drawing holds a cowl position; the cowl, duct, fan and any containment are not supplied.
  • Laboratory gases, gas lines, cylinders and manifolds.
  • RO or DI water plant, storage and distribution.
  • Waste and effluent treatment of any kind. The sink is a water and waste interface, not a treatment system.
  • Validation, qualification and accreditation of the laboratory or of any test carried out in it.
  • Site water supply, site drainage, the incoming electrical supply and the licensed connection work.
  • Delivery, unloading, placement and site supports, which are covered by the Shipping tab and the quotation.
  • Fitted air conditioning. The electrical package carries provision where the drawing calls for it; the unit itself is quoted separately.

If a requirement is not in the first list and not in the second, it has not been priced and it should be raised before the drawing is frozen rather than after. Final structural member adequacy, lifting connections and capacity, wind and seismic actions, equipment loads, the final electrical load schedule, derating and voltage drop all remain project engineering, controlled by the signed quotation and the approved fabrication drawings.

Choosing between 100, 160, 200, 240, 300 and 400 sq ft

Floor area is the wrong first question. The right one is how many bench runs the work needs, and whether the room has to hold more than one person moving at the same time. The six sizes answer those two questions in a particular order, and the table below is the short version of the GA boards in the section above.

SizeAreaBench runsSinkCleaning aisleEx-GST price
10×10×8.5 ft100 sq ft11≈ 7.34 ft₹2,30,000
20×8×8.5 ft160 sq ft11≈ 5.34 ft₹3,52,000
20×10×8.5 ft200 sq ft31≈ 5.34 ft₹4,00,000
20×12×8.5 ft240 sq ft31≈ 7.34 ft₹4,60,800
30×10×8.5 ft300 sq ft21≈ 5.34 ft₹5,76,000
40×10×8.5 ft400 sq ft21≈ 5.34 ft₹7,60,000
Compact workflow in a 10x10 ft portable mobile laboratory: a single bench run with the sample intake point and sink together on 100 sq ft

Read it this way. One person, routine screening, samples arriving in batches: the 10×10 does the job and gives the widest aisle on the page while doing it. One person but a longer sequence of operations, on ground that is a strip rather than a square: the 20×8, where the single 18.5 ft bench becomes a production line from door to sink. Two people, or one person with a dirty and a clean side to keep apart: the 20×10, which is the first size to give you three separate bench runs. The same work with a trolley in the room: the 20×12, identical to the 20×10 in every respect except that the aisle is two feet wider.

Above that the decision changes again. The 30×10 gives two external doors, which is what lets a sample entrance and a working entrance be separated by procedure. The 40×10 benches both long walls almost end to end, 67.5 ft of bench in one room, and is the largest size published from the price rule.

Why the cleaning aisle decides the width

Every GA board on this page prints one figure that a floor-area comparison will never show you: the clear cleaning aisle. It is the width of floor left between the bench faces once the benching is in, and it is the number that governs how the room actually works.

Wide aisle in a 20x12 ft portable mobile laboratory: the same three bench runs as the 20x10 with 7.34 ft of clear floor between the bench faces and no island

At 5.34 ft, which is what the 10 ft widths give once both long walls are benched, one person works comfortably and a second person passes behind them. A trolley passes, but the person at the bench steps in. At 7.34 ft, which the 10×10 gives with one bench and the 20×12 gives with three, a trolley and a working technician coexist without either stopping. Neither figure is generous by fixed-laboratory standards, and both are stated so that nobody discovers the difference after delivery.

This is also why none of the six sizes carries an internal partition, and why the 20×12 has no island bench even though it is wide enough to hold one. A partition in a 10 or 12 ft width produces a corner that cannot be reached properly with a mop, and an island produces four more of them. The coved floor junction exists to remove exactly those corners. Adding a partition back in would undo the reason the room costs what it costs.

The end walls follow the same logic. Each carries one centred 4 by 3 ft window and no external door, and each is kept furniture-free. That is not a saving; it is what keeps two of the four wall-floor junctions completely clear for cleaning and inspection.

How the price is built, and what is quoted separately

The price on this page is built from one editable rate and one published area rule, not from a quotation for each size. The base rate is ₹2,000 per square foot at 200 square feet, which is why the 20×10 is the reference size. Smaller units carry a band uplift because the fixed content of a laboratory does not shrink with the floor: a 100 sq ft room still needs a sink, a distribution board, a sealed sleeve and a coved floor. Larger units carry a band reduction.

The bands applied on this page are +15 per cent between 100 and 149 sq ft, +10 per cent between 150 and 199, no adjustment at 200, minus 4 per cent between 201 and 300, and minus 5 per cent between 301 and 400. That is how ₹2,000 becomes ₹2,300 per sq ft at the 10×10 and ₹1,900 per sq ft at the 40×10. The full ladder runs from 40 sq ft up to 900 sq ft; above 900 sq ft there is no rule price and the enquiry is quoted manually.

Every figure on this page is ex-GST for the lab-ready enclosure, with the 18 per cent GST-inclusive figure shown alongside so that nobody has to compute it. What the figure does not include is the exclusion list above. If you are comparing this page against another supplier's number, compare the exclusion lists first, because a laboratory quotation that does not mention fume hoods, gases, RO water, validation or accreditation has almost certainly left them out too, without saying so.

If the requirement is an office rather than a laboratory, the same platform is priced differently and more cheaply on the Readymade Office Cabin and Prefabricated Office Cabins pages. Ordering a laboratory finish for a room that will hold desks is money spent on a floor junction nobody will ever wash.

Water, drainage, power and the one sealed sleeve

Services are the part of a portable laboratory that goes wrong most often, and the discipline on this page is deliberately strict. One sink or service interface is shown per size, at a coordinate printed on the GA board. That interface is the point at which the unit meets site water and site drainage. The site side of it, the supply, the run, the fall and the disposal, is coordinated separately and is not in the price.

Capacity layout in a 40x10 ft portable mobile laboratory: both long walls benched almost end to end, with the sink and service interface at the far end of the workbench

Penetrations through the envelope are controlled the same way. One sealed utility sleeve is provided, and its position is frozen on the drawing before fabrication. Nothing is field-cut. If a future exhaust or an additional utility route is likely, it has to be declared and frozen at the same time, because a hole cut later through a coved and lined enclosure is a hole cut through the reason the enclosure exists. The drawing holds a cowl position as a placeholder; the exhaust itself is excluded until it is quoted.

Electrically, the unit is wired in concealed copper with a distribution board, isolation, RCCB and MCB protection, earthing and circuit segregation as scheduled. Typical starting conductors are 1.5 sq mm for lighting, 2.5 sq mm for sockets and 4 sq mm for higher-load points. Those are starting points, not the design: the final load schedule, protection, derating and voltage drop follow the approved electrical drawing, and the connection to the incoming supply is licensed work carried out on site.

Before dispatch the unit is checked for dimensions, welds, coating, drainage, weather seals, opening operation and electrical continuity. Pressure and leak, polarity, continuity, insulation, earthing and RCCB trip checks on the completed installation are project-specific and belong to the site works.

When a portable mobile laboratory is the wrong choice

It is the wrong choice when the testing has to travel. A room that is lifted by crane onto supports is not a substitute for a vehicle, and treating it as one produces a unit that gets moved twice, damaged once and then abandoned in a corner of the yard.

It is the wrong choice when the room is really an office with a bench in it. If the daily work is paperwork, approvals, drawings and meetings, with occasional sample handling, an office cabin costs less and suits better. The Readymade Office Cabin page carries that specification.

It is the wrong choice when the process needs containment. If the work requires a fume hood, a biosafety cabinet, a gas manifold or a controlled-atmosphere enclosure, the room on this page is the shell those things would sit inside, and every one of them is excluded here. Bring the containment specification first and the enclosure will be quoted around it, rather than the other way round.

And it is the wrong choice when the requirement includes a toilet inside the same unit. A wet zone needs its own waste connection and a different lining, and putting one inside a laboratory shell compromises both. Where a toilet has to be part of the same order, the Porta Cabin with Toilet is the product for it, standing alongside the laboratory rather than inside it.

Frequently asked questions

What is a mobile laboratory?

A laboratory that can be relocated rather than built in place. In India the phrase usually means a lab built into a vehicle. SAMAN's is the other kind: a factory-finished steel room that is delivered, lifted onto supports and used where it stands.

What is a mobile testing laboratory?

A relocatable room set up to run tests next to the process that produces the samples, instead of sending samples away. SAMAN supplies the lab-ready enclosure, benching and sink interface; the test instruments and any accreditation are separate.

What is a portable lab?

On this page it is a steel room finished to laboratory standard before dispatch: coved vinyl floor, washable liner, scheduled bench runs, one sink interface and one sealed utility sleeve, in six sizes from 100 to 400 sq ft.

What are the three types of laboratories?

There is no single official list. In Indian site and factory practice the three that come up are materials and quality-control labs, research labs and clinical or diagnostic labs. The enclosure on this page suits the first, and is used for sample handling and routine testing.

How much does a portable mobile laboratory cost in India?

From ₹2,30,000 ex-GST for the 10×10 ft, 100 sq ft unit, up to ₹7,60,000 ex-GST for the 40×10 ft, 400 sq ft unit. Prices are for the lab-ready enclosure and its scheduled fixed provisions, not for instruments.

Is the sink connected, and is water included?

One sink or service interface is provided per size at the coordinate shown on the GA board. Site water supply, drainage and the connection work are coordinated separately and are not in the page price. RO and DI water plant is excluded.

Can a fume hood be fitted?

Not within this price. Fume hoods, gases, process exhaust, RO or DI water, validation, accreditation and waste treatment are all excluded unless separately quoted. Tell us the containment requirement first and the enclosure is quoted around it.

How is the laboratory lifted and placed?

By four compact top-corner lifting eyes, as one rigid box, onto prepared supports. Lifting connections and capacity for the order are governed by project engineering and the approved shop drawings, not by this page.

Technical Specifications

Detailed technical information and features

These specifications describe the lab-ready enclosure in the six approved sizes. Group A is the size and price ledger. Groups B and C are what separate this page's product from the office cabins built on the same platform: the hygienic finish set, the bench and sink schedule and the wall-by-wall opening schedule. Group D is the material key shared across SAMAN's cabin families, so the build can be compared line for line with any other SAMAN cabin. Group E is the commercial boundary. Read B and C to choose a size, D to compare the build, and E before comparing the price with anyone else's.

Final member sizes, connections, lifting details and capacity, service penetrations, the electrical load schedule and site support conditions remain controlled by the signed quotation and the approved fabrication drawings. Where a row gives a standard thickness it is the cabin-family standard and the quotation confirms it for the order. Where a row records a laboratory-specific control, the control is scheduled on the approved GA drawing and its extent is confirmed at quotation.

Below the tables sit the six approved GA specification boards, one per size, each carrying the plan, the four wall elevations, the opening schedule in feet, the fixed bench and sink schedule and the clear cleaning aisle. Two coordination diagrams follow them: the frame and envelope sequence, showing where the GA and the service register are frozen and where the washable liner, cleanable junctions and coved vinyl floor are installed, and the openings and services diagram, showing window sealing, the protected electrical distribution and the single sink interface.

Group A - Approved sizes and prices

CodeSize (ft)Area (sq ft)RoofRate ₹/sq ftPrice ex-GSTPrice incl. 18% GST
SZ-0110×10×8.5100Two-way2,300₹2,30,000₹2,71,400
SZ-0220×8×8.5160One-way2,200₹3,52,000₹4,15,360
SZ-0320×10×8.5200Two-way2,000₹4,00,000₹4,72,000
SZ-0420×12×8.5240Two-way1,920₹4,60,800₹5,43,744
SZ-0530×10×8.5300Two-way1,920₹5,76,000₹6,79,680
SZ-0640×10×8.5400Two-way1,900₹7,60,000₹8,96,800

Price rule: base rate ₹2,000/sq ft at 200 sq ft. Area bands: 40-59 +44%, 60-79 +36%, 80-99 +26%, 100-149 +15%, 150-199 +10%, 200 unchanged, 201-300 -4%, 301-400 -5%, 401-500 -6%, 501-600 -7%, 601-700 -8%, 701-800 -9%, 801-900 -10%. Above 900 sq ft is quoted manually.

Group B - Laboratory finish, roof family and lifting (product-specific)

ItemSpecification
Product boundaryLab-ready enclosure and scheduled fixed provisions; non-container material and roof family
Floor finishCoved vinyl: the floor-to-wall junction is formed as a radius, not a square corner
Wall and ceiling linerWashable liner with cleanable junctions over a non-absorbent substrate
Bench substrateNon-absorbent, scheduled by run on the approved GA drawing
Service penetrationOne sealed utility sleeve, position frozen on the drawing before fabrication; nothing field-cut
ExhaustCowl position held on the drawing as a placeholder only; cowl, duct, fan and containment excluded
Contamination controlOpen lab room, no internal partitions and no island bench in any size; contamination break point named on the drawing
Reagent storageAllowance scheduled as upper storage modules: 2 at 10×10, 3 at 20×8, 4 at 20×10, 20×12 and 30×10, 5 at 40×10
Roof, 8 ft widthOne-way: one plane falling across the width, 5-6 in total high-to-low fall (20×8 only)
Roof, 10 and 12 ft widthsTwo-way: one continuous centred longitudinal ridge, two planes falling to the long-wall eaves, ridge 5-6 in above each eave
LiftingExactly four compact top-corner lifting eyes; no ISO corner castings
Wall thickness100 mm
Height8.5 ft nominal, all sizes
Presentation colours10×10 deep bottle green · 20×8 muted teal · 20×10 pearl off-white · 20×12 deep oxford blue · 30×10 burgundy wine · 40×10 slate blue-grey; final colour confirmed at quotation

Every row in this group is scheduled on the approved GA boards shown in the size section above. Extent and material certification are confirmed at quotation.

Group C - Opening, bench and sink schedule by size (from the GA boards)

SizeWall AWall BEnd C / End DFixed benches and sinkClear cleaning aisle
10×101 door at 3.5-6.5 ft1 window at 3-7 ft1 centred 4×3 ft window each, no doorB1 Wall B 1-9 ft; sink 7-8.5 ft≈ 7.34 ft
20×8window 1.5-5.5, door 8.5-11.5, window 14.5-18.5 ftwindows at 1.5-5.5 and 14.5-18.5 ft1 centred 4×3 ft window each, no doorB1 Wall B 0.75-19.25 ft (18.5 ft); sink 16.75-18.25 ft≈ 5.34 ft
20×10window 1.5-5.5, door 8.5-11.5, window 14.5-18.5 ftwindows at 1.5-5.5 and 14.5-18.5 ft1 centred 4×3 ft window each, no doorB1 Wall A 0.75-7.75 ft, B2 Wall A 12.25-19.25 ft, B3 Wall B 0.75-19.25 ft; sink 16.75-18.25 ft≈ 5.34 ft
20×12window 1.5-5.5, door 8.5-11.5, window 14.5-18.5 ftwindows at 1.5-5.5 and 14.5-18.5 ft1 centred 4×3 ft window each, no doorB1 Wall A 0.75-7.75 ft, B2 Wall A 12.25-19.25 ft, B3 Wall B 0.75-19.25 ft; sink 16.75-18.25 ft; no island≈ 7.34 ft
30×10door 1.5-4.5, window 8-12, window 18-22, door 25.5-28.5 ftwindows at 1.5-5.5, 8.5-12.5, 17.5-21.5, 24.5-28.5 ft1 centred 4×3 ft window each, no doorB1 Wall A 12.75-17.25 ft (4.5 ft), B2 Wall B 0.75-29.25 ft (28.5 ft); sink 25.5-27 ft≈ 5.34 ft
40×10door 1.5-4.5, window 8-12, window 18-22, window 28-32, door 35.5-38.5 ftwindows at 3-7, 13-17, 23-27, 33-37 ft1 centred 4×3 ft window each, no doorB1 Wall A 5.5-34.5 ft (29 ft), B2 Wall B 0.75-39.25 ft (38.5 ft); sink 34-35.5 ft≈ 5.34 ft

Coordinates are measured along the named wall from its origin, as printed on the GA board for that size. End walls remain furniture-free. Instruments shown in the photographs are customer-supplied and are not part of the schedule.

Group D - Cabin-family material key (platform common; SAMAN master, Common Material Key)

ComponentApproved standardTypical size / thicknessControl
Primary base frameWelded MS C-channel chassis100×50×3 mmJoint, support and lifting design follow completed unit weight and approved GA/BOM
Upper, wall and roof frameMS SHS/angle framing with reinforced openingsTop 50×50×1.6 mm; roof 50×50×1.2 mm with listed secondary members; posts 50×50×2 mm or approved 60×60 angleMember spacing and alternatives require structural and fabrication approval
External wallsCorrugated MS sheet, Tata/Jindal or approved equivalent1.2 mmFinish colour only; FRP construction excluded
Roof sheetSloped corrugated MS sheet with sealed laps, flashings and drainage1.4 mmDrainage slope, joint seal and overhang follow the approved drawing
Internal wall and ceilingPrelaminated MDF with aluminium joint sections is the dry-cabin standard; wet and hygienic areas use approved moisture-tolerant fibre-cement hygienic lining8 mm dry standardThe laboratory finish set in Group B governs on this page
Floor systemCement-fibre (Bison) board plus resilient finish18 mm board + 1.3 mm vinylWet or heavy-use floors require a documented non-ceramic safety finish and a support check
Thermal insulationGlass wool, or documented Heatlon wall optionRoof 50 mm at 42 kg/m³; wall 25 mm glass wool or 12 mm HeatlonFinal certificate and moisture strategy confirmed at quotation
Main doorOutward-opening MS-framed door assemblyApproximately 7×3 ftDoor count, clear opening and weather seal follow the plan
WindowsTwo-track aluminium sliding unit with glazing4 mm glassCount and position per the GA schedule; end walls 4×3 ft centred
ElectricalConcealed copper wiring with DB, MCB/RCCB, earthing and circuit segregationTypical starting circuits 1.5 / 2.5 / 4 sq mmFinal load schedule, protection, derating, voltage drop and licensed connection follow the approved electrical drawing
Corrosion protectionPrepared MS with red-oxide primer and compatible enamelOne primer + two enamel coatsCoastal or chemical exposure may require a separately approved coating system
Handling and QADesigned lifting eyes, sealing and pre-dispatch inspectionCompleted-unit specificDimensions, welds, sheets, coating, drainage, seals, openings, electrical continuity and function checked before dispatch

This key is the common standard for SAMAN's Porta Cabin, Portable Cabin, Portable Office, Prefabricated House and Security Cabin families. Where Group B states a laboratory-specific finish, Group B governs.

Group E - Scope boundary

Included in the page priceSeparately quoted or excluded
Lab-ready enclosure in one of the six listed sizesInstruments, analysers and all loose equipment
Coved vinyl floor, washable liner, non-absorbent substrateFume hoods, biosafety cabinets and any containment
Fixed bench runs and upper storage modules per the GA scheduleProcess exhaust: cowl, duct, fan and controls
One sink or service interface at the scheduled coordinateLaboratory gases, lines, cylinders and manifolds
One sealed utility sleeve, frozen on the drawingRO or DI water plant, storage and distribution
Standard electrical package with DB, RCCB/MCB and earthingWaste and effluent treatment
GA-fixed door and window scheduleValidation, qualification and accreditation
Four compact top-corner lifting eyesSite water, drainage, incoming supply and licensed connection
Ex-GST and GST-inclusive prices for the six approved sizesDelivery, unloading, placement, site supports and fitted AC

A requirement that appears in neither column has not been priced. Raise it before the drawing is frozen.

GA specification board for the 10x10x8.5 ft portable mobile laboratory: plan and four elevations, one door on Wall A, one window on Wall B, one centred window per end wall, single bench run with sink, clear cleaning aisle 7.34 ft
GA specification board for the 20x8x8.5 ft portable mobile laboratory: window-door-window on Wall A, two windows on Wall B, one continuous 18.5 ft bench with the sink at 16.75 to 18.25 ft, one-way roof
GA specification board for the 20x10x8.5 ft portable mobile laboratory: three fixed bench runs, sample intake and equipment allowance benches on Wall A, 18.5 ft workbench on Wall B, clear cleaning aisle 5.34 ft
GA specification board for the 20x12x8.5 ft portable mobile laboratory: the 20x10 bench and opening schedule on a 12 ft width, no island bench, clear cleaning aisle 7.34 ft
GA specification board for the 30x10x8.5 ft portable mobile laboratory: two external doors on Wall A, eight windows, 4.5 ft intake bench and 28.5 ft workbench, sink at 25.5 to 27 ft
GA specification board for the 40x10x8.5 ft portable mobile laboratory: two external doors, nine windows, 29 ft and 38.5 ft bench runs, sink at 34 to 35.5 ft, clear cleaning aisle 5.34 ft
Frame and envelope workflow diagram for the portable mobile laboratory: prepare and align the frame and freeze the GA and service register, tack and weld, then install the washable liner, cleanable junctions and coved vinyl floor
Openings and service coordination diagram for the portable mobile laboratory: sealing each opening on the GA coordinates, protected electrical distribution with RCCB and MCB, and the single sink and utility interface

Download technical specification (PDF)

Shipping & Delivery

Freight tables and delivery terms

Every SAMAN cabin is delivered factory-direct from our Bengaluru (South) or Greater Noida (North) unit on an open trailer, with delivery and installation across South and North India in 7–21 working days. Cabins up to 20 ft travel on a 20 ft open trailer; 30 ft and 40 ft cabins travel on a 40 ft open trailer. Unloading by crane or manual placement is arranged based on your site access and confirmed at quotation.

Free delivery: within Bangalore city (South zone) · Delhi NCR: Ghaziabad, Gurugram, Faridabad, Noida and Greater Noida (North zone).

20 ft open trailer · freight by distance (both zones)

DistanceFreight (Rs)
100–150 km25,000–30,000
150–200 km30,000–35,000
200–250 km35,000–40,000
250–300 km40,000–45,000
300–350 km45,000–50,000
350–400 km50,000–55,000
400–450 km55,000–60,000
450–500 km60,000–65,000
500–550 km65,000–70,000
550–600 km70,000–75,000
600–650 km75,000–80,000
650–700 km80,000–85,000
700–750 km85,000–90,000
750–800 km90,000–95,000
800–850 km95,000–100,000
850–900 km100,000–105,000
900–950 km105,000–110,000
950–1,000 km110,000–115,000

40 ft open trailer · freight by distance (both zones)

DistanceFreight (Rs)
100–150 km30,000–35,000
150–200 km35,000–40,000
200–250 km40,000–45,000
250–300 km45,000–50,000
300–350 km50,000–55,000
350–400 km55,000–60,000
400–450 km60,000–65,000
450–500 km65,000–70,000
500–550 km70,000–75,000
550–600 km75,000–80,000
600–650 km80,000–85,000
650–700 km85,000–90,000
700–750 km90,000–95,000
750–800 km95,000–100,000
800–850 km100,000–105,000
850–900 km110,000–115,000
900–950 km115,000–120,000
950–1,000 km120,000–125,000

Typical destinations from our Bengaluru unit (South zone)

approximate road distance, find your freight band in the tables above; final charge confirmed at quotation

CityApprox. distanceFreight band
Mysuru~145 km100–150 km
Salem~215 km200–250 km
Tirupati~250 km250–300 km
Mangaluru~350 km300–350 km
Chennai~350 km300–350 km
Coimbatore~365 km350–400 km
Hubballi~410 km400–450 km
Madurai~435 km400–450 km
Kochi~550 km500–550 km
Goa (Panaji)~560 km550–600 km
Hyderabad~570 km550–600 km
Vijayawada~630 km600–650 km

Typical destinations from our Greater Noida unit (North zone)

approximate road distance, find your freight band in the tables above; final charge confirmed at quotation

CityApprox. distanceFreight band
Agra~165 km150–200 km
Haridwar~230 km200–250 km
Jaipur~255 km250–300 km
Dehradun~285 km250–300 km
Chandigarh~290 km250–300 km
Gwalior~330 km300–350 km
Ludhiana~390 km350–400 km
Kanpur~440 km400–450 km
Lucknow~470 km450–500 km
Amritsar~490 km450–500 km
Bhopal~600 km550–600 km
Varanasi~760 km750–800 km

Distances beyond 1,000 km are quoted at booking. ODC (over-dimensional cargo) charges depend on the state. All freight figures are tentative, the final charge is confirmed once your delivery location and order are confirmed, and may vary slightly with the route and return-vehicle availability.

Customer Reviews

0 reviews

No verified reviews yet.

Write a Review for Portable Mobile Laboratory

Your email is not published.

Reviews are published after approval by our team.

Built by a verified manufacturer: ISO 9001:2015 certified, Udyam registered, NSIC-enlisted, GST registered.

View manufacturer credentials