PUF Porta Cabin with Insulated Sandwich Panel Walls

Choose your size - six factory-built options

20x10 ft PUF Porta Cabin

₹2,45,000 + GST

₹2,89,100 incl. 18% GST

The PUF Porta Cabin is a transportable steel-chassis cabin whose walls and roof are factory-made PUF sandwich panels. The panel face is the finished surface inside and out, so we fit no separate lining on site. The planning build uses 50 mm wall panels and 60 to 80 mm roof panels with pre-coated GI or GL facings, sealed interlocking joints and service openings planned before manufacture.

Choose it when people will occupy the room through an Indian summer and the interior has to look finished from day one. Panel brand, skin thickness, core density, thermal data and fire classification are named in the purchase order and confirmed by supplier certificate. None of them can be read off a panel thickness.

Size
20x10x8.5 ft
Material
MS chassis with 50 mm PUF panel envelope
Delivery
7-21 working days
Coverage
Bangalore · Delhi NCR
Brand
SAMAN Portable
Application
General site office, reference build

Custom sizes available · 500+ projects delivered · Factory-tested before dispatch

Download Specification PDF

GST registered · ISO 9001:2015 certified manufacturer · 5-year structural and 1-year finishing warranty · Pan-India delivery

When a PUF Panel Envelope Beats a Framed and Lined Cabin

Choosing the right cabin is easier when you focus on how the space will actually be used. If you need a comfortable, insulated room that looks finished as soon as it arrives, a PUF panel cabin often makes more sense.

Cream PUF panel cabin with brown trim, showing flat panel faces and visible vertical panel joints

One panel does three jobs

A framed cabin carries insulation inside a structural shell, so the wall builds up in layers and the lining becomes a separate trade. A PUF cabin inverts that. The panel is the wall: outer skin, insulated core and finished inner face arrive as one factory element, and the steel takes its sizing from that panel's span. You gain a continuous insulated envelope and a clean interior on day one. You accept a discipline in exchange, because the core cannot be cut open for services after the fact.

That trade suits occupied rooms in hot climates and any project where the interior has to look finished immediately. Where the priority is a heavy fixed-position industrial shell instead, the MS porta cabin answers it better. Send us your site conditions and opening schedule and we will quote the panel system against them.

Explore the project gallery
Blue PUF porta cabin on a paved apron with an elevated flyover and site fencing behind

20x10 ft PUF Cabin: The Reference Build for Pricing

This is the reference configuration for the whole specification. The Rs 1,225 per square foot Cost Estimation Input is set here, and every other size derives from it through the area band adjustment. The 30 technical line items describe this build, and the specification document is written around it. Choose it when nothing pushes you narrower or longer, because it gives the most conventional room proportion and the specification everyone can check against.

20x10x8.5 ft200 sq ft₹2,45,000 + GST1,225.00/sq ft

20x10 ft

₹2,45,000 + GST

SAMAN Portable

PRICE IT YOURSELF

Your PUF Porta Cabin from ₹1,40,875

Set the size, choose the finish, watch the price move as you go.

Start your design

Fixed-price quote within 48 hours. Built in our own works.

Customized cabin

PUF Porta Cabin

20×10 ft · 200 sq ft

Estimated total

₹2,10,980₹2,48,956 incl. GST

Step 1 of 9

Choose your product

Pick the building closest to what you need. You can change it at any point.

Choose your product

Set the size

Area and price update as you type. Every size prices from our base-cabin rate card — the larger the floor area, the lower the rate per square foot.

Enter a length and width between 4 and 60 ft. For larger buildings, request a quotation and we will size it with you.

Rooms and partitions
Partition doors
Drawing view
D1W1W220' 0"10' 0"2D Plan

R = room · D = door · W = window

On the drawing, R1 is Room 1, D1 is Door 1 and W1 is Window 1. Every control and every line of your quotation uses the full words.

Carpet Area200 sq ft
Base cabin price₹2,00,000
Roof
Mobility

Enter any size you need. All sizes price from the same base-cabin rate card, and your figure is confirmed on the drawing.

Frame and wall

Choose what the cabin is built from. The frame carries the load, the wall closes it, and both move the price.

Structural frame
Wall construction

Choose the interior

Standard finishes are included. Upgrades and savings are shown per square foot.

Internal wall lining, per sq ft of wall
Ceiling, per sq ft of floor
Flooring, per sq ft of floor
Wall build-up from outside to inside
Weather skin50
Structural faceMS frame & panel support
Thermal layer50 PUF
Added insulation, per sq ft of wall and ceiling

Add doors and windows

Set the type, the count and where each one sits. The plan updates as you choose.

Door placement

Door 1
Hinge side
Opening
Use "In" when hand flow should remain inside the room edge. Use "Out" when swing clearance is outside.

Window placement

Window 1
Track
Track choice affects how much frame is needed along the edge.
Window 2
Track
Track choice affects how much frame is needed along the edge.

If the entrance sits under a shed or a covered walkway, choose opens in, so rain does not blow through the doorway. On an open site choose opens out, because the door seals tighter against wind. Hinge left and hinge right set which side the handle falls on.

A 2.5 track slides more smoothly and costs more than a 2 track. The difference scales with the size of the window.

Drawing view
D1W1W220' 0"10' 0"2D Plan

R = room · D = door · W = window

On the drawing, R1 is Room 1, D1 is Door 1 and W1 is Window 1. Every control and every line of your quotation uses the full words.

Carpet Area200 sq ft
Base cabin price₹2,00,000

Add electrical fittings

Tick what you need. Quantities are suggested from the floor area and you can change every one.

Light colour
LED shape
Socket placement, no cost impact

Placement moves a socket, it does not add one. The charge is the plug point count above, and moving a socket costs nothing.

Front
Rear
Left
Right
Drawing view
D1W1W220' 0"10' 0"2D Plan

R = room · D = door · W = window

On the drawing, R1 is Room 1, D1 is Door 1 and W1 is Window 1. Every control and every line of your quotation uses the full words.

Carpet Area200 sq ft
Base cabin price₹2,00,000

Add furniture and fittings

Everything here is optional. Add only what you want fitted before delivery.

Some fit-out components are being confirmed and show as Quoted separately.

Furniture position

Delivery and taxes

Transport and installation are optional and depend on your site. GST is shown as its own line.

Delivery scope
See the full distance ladder
Delivery freight ladder, ex-GST
Distance20 ft trailer40 ft trailer
Bangalore cityFreeFree
Delhi NCRFreeFree
Under 100 kmConfirmed at quotationConfirmed at quotation
100-150 km₹27,500₹32,500
150-200 km₹32,500₹37,500
200-250 km₹37,500₹42,500
250-300 km₹42,500₹47,500
300-350 km₹47,500₹52,500
350-400 km₹52,500₹57,500
400-450 km₹57,500₹62,500
450-500 km₹62,500₹67,500
500-550 km₹67,500₹72,500
550-600 km₹72,500₹77,500
600-650 km₹77,500₹82,500
650-700 km₹82,500₹87,500
700-750 km₹87,500₹92,500
750-800 km₹92,500₹97,500
800-850 km₹97,500₹1,02,500
850-900 km₹1,02,500₹1,07,500
900-950 km₹1,07,500₹1,12,500
950-1000 km₹1,12,500₹1,17,500

Delivery in 7 to 21 working days. Freight is confirmed once the exact delivery location and order are approved.

Get your quotation

Send us this configuration and we will confirm it with a fixed price within 48 hours.

Submit the exact configuration for a fixed, itemised quotation within 48 hours.

Your contact detailsEnter a 10-digit Indian mobile number.Please add your email so we can send your quotation PDF.

Please add your name and mobile number so our sales team can send your fixed quotation.

Published cabin price tables

All primary prices are ex-GST. Including-GST figures apply 18 percent GST.

Porta Cabin price table
Porta Cabin published size and price ladder
SizeAreaPrice ex-GSTIncluding 18% GST
10x10 ft100 sq ft₹1,40,875₹1,66,233
20x8 ft160 sq ft₹2,15,600₹2,54,408
20x10 ft200 sq ft₹2,45,000₹2,89,100
20x12 ft240 sq ft₹2,82,240₹3,33,043
30x10 ft300 sq ft₹3,52,800₹4,16,304
40x10 ft400 sq ft₹4,65,500₹5,49,290
Indicative estimate SP-EST · 16 Aug 2026 · Fixed, itemised quotation within 48 hours of submission.

You may also like

Product Details

Comprehensive information about PUF Porta Cabin

Product Overview

Detailed information about PUF Porta Cabin

What a PUF porta cabin actually is

A PUF porta cabin is a transportable building whose walls and roof are factory-made sandwich panels rather than a frame with insulation added inside it. Each panel arrives as one finished element. It carries a pre-coated steel skin outside, a rigid polyurethane foam core in the middle, and a second pre-coated steel skin inside. That inner skin becomes the visible wall surface of the room.

That single sentence carries most of the difference. In a framed and lined cabin, insulation is a layer inside a shell, and the interior finish is a separate material fixed over it. Here the insulation, the weather skin and the interior finish are the same component. The steel structure underneath still does the structural work. Its sizing follows what the chosen panel can span rather than what a cladding sheet needs.

The standard planning build uses 50 mm wall panels and 60 to 80 mm roof panels. Facings are pre-coated GI or GL in the 0.5 to 0.8 mm range that the panel industry typically supplies. We offer an 80 mm wall panel where a project needs higher insulation. The chassis is a 100 x 50 x 3 mm MS C-channel reference frame. The floor sits on an MS cross-grid and uses an 18 mm cement-bonded board, with a 24 mm option for higher duty.

Cream PUF panel cabin with brown trim, showing flat panel faces and visible vertical panel joints
Flat sandwich panel faces with the panel joints visible. The inner face of the same panel is the finished wall.

Where the panel build earns its money

Rooms people occupy through the summer

The clearest case is a room somebody sits in all day, in a place that gets genuinely hot. A continuous insulated envelope with sealed joints cuts the heat reaching the inside face. It also cuts the air leakage that makes an air-conditioned cabin expensive to hold at temperature. Site offices, control rooms, testing rooms and any cabin with instruments or people in it for a full shift are the honest applications.

Space that has to look finished immediately

Because the panel inner face is the finished wall, a PUF cabin does not need a lining trade on site. There is no MDF to fit, no joint to fill, no surface to paint before anyone moves in. A cabin delivered on Tuesday can be occupied on Tuesday. For marketing offices, client-facing site offices and anything a visitor will walk into, that matters as much as the thermal performance.

Interiors that need a wipeable surface

The pre-coated steel inner face is a hard, smooth, cleanable surface. That suits rooms where dust, handling or hygiene expectations make a soft lining a liability. This is not a clean-room specification and we do not claim one. The base surface simply starts from a better place than a board lining.

The envelope, layer by layer

Wall panels: 50 mm standard, 80 mm option

Fifty millimetres is the standard planning thickness. The published price ladder costs against this thickness, and it suits most site offices in most Indian conditions. Eighty millimetres is the documented higher-insulation option. Specify it when the cabin faces long solar exposure, when air-conditioning load drives your operating cost, or when the room must hold temperature with plant running outside.

Thickness is a planning decision, not a performance certificate. Core density and thermal conductivity come from the panel supplier's certificate for the system you actually buy, and the purchase order names them. We publish no conductivity figure or U-value for the cabin. A cabin figure would have to account for the frame, the joints, the openings and the installation, and none of that is fixed until the design is.

Roof panels: why the range is 60 to 80 mm

The roof gets more thickness than the walls for a simple reason. It takes the most direct solar gain, it spans further, and it has to carry drainage and any service loads. The factory roof panel gives you weather skin, insulation and finished underside in one element. Its outer skin is profiled and its inner liner arrives finished.

Where the roof lands inside the 60 to 80 mm range depends on heat gain, on the span the design needs, and on condensation requirements. The panel supplier's structural and thermal data governs the allowable span and the fastener spacing. We therefore coordinate the roof secondary members to the panel rather than assume them. These are typically 50 x 50 x 1.2 mm and engineered as the span requires.

Yellow PUF panel cabin in a gravel yard, long panel run with three windows and a charcoal door
A longer run means more panel joints and a longer roof drainage path, both planned before manufacture.

Facings, joints and why sealing decides the result

A good panel installed with poor joints performs like a poor panel. The controls that matter are unglamorous. We use interlocking joint profiles, corrosion-compatible mechanical fasteners, EPDM or butyl or approved sealants, and flashings at joints, corners, roof laps and every penetration.

We accept no unsealed field cut. Every cut edge exposes the core, and an exposed core is where water, vapour and time get in. Where a cut has to happen, we close it with the approved flashing and sealant detail before the panel passes inspection.

The steel under the panels

It is worth being explicit about this, because the panel is the visible part and it is easy to assume it does everything. It does not. The transport and lifting chassis remains structural steel, and we size it independently for cabin loads and for handling. Panel fasteners never substitute for structural connections.

The reference build uses a 100 x 50 x 3 mm MS C-channel bottom frame. Stiffeners in 100 x 50 and 75 x 40 channel and square pipe support the floor loads and the panel perimeter rails. A 50 x 50 x 1.6 mm MS SHS top frame gives the wall panel heads a straight, level bearing. Wall framing is 50 x 50 x 2 mm MS SHS, with framed openings locally reinforced.

That last point has a practical consequence. Large openings need local reinforcement, and we design that reinforcement in rather than cut or crush the panel core to get it. A wide window or a double door is a structural decision taken before manufacture, not an adjustment made later.

Lifting and handling points are engineered provisions. We move a completed module only to the approved lifting, support and transport drawing. We weld or bolt structural connections to approved shop drawings, deburr and inspect edges, and close panels only after the frame passes inspection.

Services: planned before manufacture, never cut in later

This is the single discipline that separates a PUF cabin that lasts from one that disappoints, and it is the thing most buyers are never told.

You cannot route services by cutting channels through a sandwich panel. Doing so removes core, breaks the vapour path and leaves an unsealed edge inside the wall where nobody will ever see it fail. So we settle the service strategy before the panels are made.

In practice that means:

  • Wiring runs in planned chases and raceways, or in surface containment, rather than in improvised cuts.
  • Copper wiring follows the standard starting schedule: 1.5 sq.mm for lighting, 2.5 sq.mm for sockets, 4 sq.mm for higher-load or air-conditioning circuits. The load schedule and the approved electrical drawing set the final sizes.
  • We provide a distribution board with MCB and RCCB protection, earthing, and segregation of lighting, socket, wet-area and air-conditioning circuits, to the approved drawing.
  • Plumbing, where you order it at all, uses factory-planned sleeves and chases. We seal every penetration and protect the core, and we plan service zones and removable covers before manufacture.
  • We plan air-conditioning sleeves and condensate drains at the factory, so we restore insulation and vapour sealing around each penetration rather than patch it later.

Final quantities of lights, switches, sockets, fan points and air-conditioning provision stay quotation-specific, and we coordinate them with the approved layout. We do not publish fixed counts, because a count that is right for one layout is wrong for the next.

Off-white PUF panel office interior with wall-mounted split AC, recessed downlights and wood-look floor
The wall AC and its sleeve are planned at the factory so insulation and vapour sealing are restored around the penetration.

Condensation, ventilation and air conditioning

An insulated, well-sealed box behaves differently from a leaky one, and that is mostly the point. It also means the ventilation strategy has to be chosen deliberately rather than left to the gaps.

We select the ventilation approach for occupancy and climate. It may use natural ventilation through the opening schedule, or air conditioning with controlled condensate. What it must not be is uncontrolled vapour movement through panel joints, because that is how moisture reaches places it cannot dry from.

Where a false or service ceiling is added below the insulated roof, it creates a void for services. It does not replace the roof panel's thermal function, and the vapour and condensation control has to stay continuous above it. That distinction is easy to lose on site and expensive to rediscover later.

What a PUF panel does not do

Two limits deserve stating plainly, because the market around this product is not always honest about them.

The first is fire. Fire resistance cannot be inferred from PUF thickness. A thicker PUF panel is a better insulator; it is not a fire rating. Where a project requires a non-combustible core, the answer is a tested mineral-wool panel system rather than more polyurethane. That is a different build with a different specification. If fire performance is what your project is actually buying, start at the fire-rated porta cabin instead of specifying this one and hoping.

The second is that a panel is not a structure. The chassis carries the building. The panel closes it, insulates it and finishes it. Treat with suspicion any claim that a sandwich panel cabin needs less steel because the panels are strong.

Choosing between 50 mm and 80 mm

The honest guidance is narrower than most buyers expect.

Specify 50 mm for a normal site office in normal conditions. It suits cabins where air conditioning runs during working hours rather than continuously, and cabins you expect to relocate within a few years. This is the standard build, and the published prices cover it.

Specify 80 mm where solar exposure runs long and unshaded, or where the room must hold a set temperature against a continuous heat load. It also earns its cost when air-conditioning running cost over a multi-year deployment is a real line in your budget, and on semi-permanent cabins.

Specify neither on the basis of a number you found on a competitor's page. Panel data belongs to the panel you actually buy, and the supplier issues it as a certificate against that purchase order.

Standard, optional, custom and excluded

ScopeWhat it covers on this page
STANDARDMS chassis and framing to the reference sections, 50 mm PUF wall panels, 60 to 80 mm PUF or PIR roof panel, factory-finished inner faces, 18 mm cement-bonded floor base with 1.5 to 2.0 mm commercial vinyl, insulated door assembly, sealed aluminium windows, lighting, sockets, DB with MCB and RCCB, earthing, pre-dispatch QA
OPTIONAL80 mm wall panel, 24 mm floor base, SPC or epoxy floor finish, decorative or hygienic inner lining, service ceiling below the insulated roof, upgraded glazing, grills, mesh, guards or louvers, air-conditioning provision, plumbing with planned sleeves
CUSTOMNon-standard footprints, framed structural openings, partitioned layouts, project-selected colour and coating system, panel system nominated by the client
EXCLUDEDInterior fit-out and furniture, transport and installation, foundations, offloading and craneage, project-specific engineering, performance testing and certification, GST

We publish this table because the most common source of dispute on a modular building is not the price. It is the boundary between what arrived and what somebody assumed would arrive.

Sage green PUF panel cabin on a gravel yard, showing the steel base frame below the panel walls
The steel chassis under the panels carries the building. The panels close, insulate and finish it.

Six sizes and published prices

SizeAreaRate per sq.ft.Price ex-GSTWith 18% GST
10x10x8.5 ft100 sq.ft.Rs 1,408.75Rs 1,40,875Rs 1,66,233
20x8x8.5 ft160 sq.ft.Rs 1,347.50Rs 2,15,600Rs 2,54,408
20x10x8.5 ft200 sq.ft.Rs 1,225.00Rs 2,45,000Rs 2,89,100
20x12x8.5 ft240 sq.ft.Rs 1,176.00Rs 2,82,240Rs 3,33,043
30x10x8.5 ft300 sq.ft.Rs 1,176.00Rs 3,52,800Rs 4,16,304
40x10x8.5 ft400 sq.ft.Rs 1,163.75Rs 4,65,500Rs 5,49,290

These are derived planning estimates, and we confirm the panel system at quotation. The rate falls as the footprint grows because the envelope, the openings and the services scale with perimeter rather than with floor area. Interior fit-out, optional add-ons, transport, installation, foundations and any project-specific engineering or testing sit outside these figures. The wider porta cabins range covers the other configurations in this cluster if the insulated build is not what your site needs.

If you want the panels on their own rather than a finished cabin, we supply PUF panels separately and price them by thickness.

Site readiness and handover

A PUF cabin asks for the same site preparation as any other module in the range, with two additions worth planning for.

Prepare a level, load-bearing base with drainage away from the cabin footprint. Pedestal or plinth support at the designed positions matters more here than on a framed cabin. A module that sits out of level puts the panel joints out of line, and joints out of line do not seal as designed.

Keep the panel faces protected during offloading and positioning. A pre-coated skin is the finished surface, so a gouge is not a scratch on a cladding sheet, it is damage to the finished wall. Touch-up is possible, and we match the corrosion protection system to substrate and exposure, but prevention costs nothing.

Pre-dispatch quality checks cover dimensions, member and panel identification, connections, coating, roof drainage, weather sealing, doors, windows, electrical continuity and functional checks. We verify specialist performance certificates where the product requires them.

The final quotation confirms warranty period and exclusions. Relocation damage, misuse, site services, consumables and unapproved alterations sit outside the agreed scope unless the quotation explicitly includes them.

Beige PUF panel cabin in a factory yard with a glazed end door and a visible module junction seam
Modules are set level so the panel joints line up. Joints out of line do not seal as designed.

What we need to quote accurately

A PUF cabin quotation moves faster when these are settled at enquiry:

  • Footprint and quantity, and whether the cabin is a standalone module or part of a linked set.
  • Wall panel thickness, 50 mm or 80 mm, and whether the roof sits at 60 mm or 80 mm.
  • Any nominated panel system or brand, or confirmation that we may propose one.
  • Opening schedule: door type and position, window sizes and positions, and any framed structural opening.
  • Service requirements: lighting and socket layout, air-conditioning provision and sleeve positions, and whether plumbing is in scope.
  • Floor duty, so we can confirm 18 mm or 24 mm base and the finish.
  • Site access, approach width, offloading arrangement and the delivery location for freight.
  • Colour and coating preference, and whether the cabin is a short deployment or semi-permanent.

Anything we cannot confirm from that list stays a quotation input rather than a website claim.

Off-white PUF panel meeting room interior with a boardroom table, chairs, split AC and ceiling LED panels
Layout, opening schedule and service positions are settled at enquiry, not after the panels are made.

Questions buyers actually ask

Is a PUF cabin cooler than a standard site office? A continuous insulated envelope with sealed joints reduces heat transfer and air leakage, and buyers report that as a more comfortable room. We publish no temperature difference. The honest answer depends on orientation, glazing, ventilation, occupancy and the air-conditioning system, and the design fixes none of those until it is complete.

Can I get a U-value or a thermal conductivity figure? For the panel you actually buy, yes, from the supplier's certificate, and the purchase order names it. For the finished cabin as an assembly, that needs a defined calculation or test method covering the frame, joints and openings. We quote a cabin figure only against such a method.

Is PUF fire resistant? No, not by virtue of being PUF, and not more so because it is thicker. Where a project requires a non-combustible core, a tested mineral-wool panel system replaces PUF.

Can I cut a new opening after delivery? Not without a designed detail. We protect the core, then seal and flash the cut edge, and larger openings need local reinforcement. Tell us at enquiry if a future opening is likely.

Does the interior need painting? No. The panel inner face is the finished surface. A decorative or hygienic lining is a separate order if you want one.

Is the 80 mm option worth it? It is worth it for long solar exposure, continuous temperature holding, or a multi-year deployment where air-conditioning running cost matters. For a normal site office on a normal programme, 50 mm is the specification we would recommend.

Technical Specifications

Detailed technical information and features

Two rows in these tables change more for the buyer than the rest combined. The first is Interior walls, because no separate MDF lining is why a PUF cabin needs no finishing trade on site and why the room is usable on delivery day. The second is Wall insulation, because the note attached to it is the one the market keeps getting wrong: thickness buys insulation, never fire performance. Read those two rows first, then read the door, window and ventilation rows together, because openings and penetrations are where a good panel build is usually lost.

Table 1: structure, chassis, envelope, roof and floor

ComponentDetail
Bottom frameStandard MS primary chassis - 100 x 50 x 3 mm MS C-channel reference: The chassis is sized independently for cabin loads and handling. Panels are enclosure components, not structure.
Bottom stiffenersMS base stiffeners - 100 x 50 / 75 x 40 channel and square pipe as engineered: Stiffeners carry floor loads and support the panel perimeter rails.
Floor frameFloor support frame - MS cross-grid with 18 mm cement-bonded or Bison board: The grid is isolated from external water ingress and gives a rigid finish-ready floor. Higher loads may need 24 mm board or steel deck.
Top framePanel-support top perimeter - 50 x 50 x 1.6 mm MS SHS reference: Gives wall panel heads a straight, level bearing. Final section and spacing follow span and handling design.
Roof stiffenersInsulated roof support frame - 50 x 50 x 1.2 mm or engineered members as panel span requires: Coordinated with the chosen panel's allowable span, fixings, overhang, drainage and service loads.
Corner posts and wallsPanel-support wall frame - 50 x 50 x 2 mm MS SHS reference, framed openings reinforced: Large openings need local reinforcement designed in, without crushing or cutting the PUF core.
Lifting and handlingApproved handling provision - Engineered lifting and support points: The completed module moves only to the approved lifting, support and transport drawing.
Welding and fabricationFabrication control - Welded and bolted connections to approved shop drawings: Qualified welding and bolting, deburred edges, dimensional inspection, panels closed only after frame inspection.
Exterior wallsPUF insulated wall sandwich panel - 50 mm default, 80 mm higher-insulation option, 0.5-0.8 mm pre-coated GI or GL facings: Skin thickness, core density, panel thickness and joint profile are stated in the purchase order.
RoofPUF or PIR insulated roof panel - 60-80 mm default range, profiled outer skin with finished inner liner: One element gives weather skin, insulation and finished underside. Fixings, laps, flashings, sealants and drainage follow the panel system.
Floor baseRigid floor base - 18 mm cement-bonded or Bison board, 24 mm option: Mechanically fixed to the chassis grid and sealed at edges. Wet or heavy-duty uses need a separately specified substrate and waterproofing.
Floor finishStandard resilient floor finish - 1.5-2.0 mm commercial vinyl, optional SPC or epoxy: Independent of wall panel thickness. Fit-out packages stay outside the base cabin price.
Decorative and external finishCoating and facade finish - Project-selected colour and compatible coating system: Substrate preparation, compatibility, touch-up and exposure-category maintenance are confirmed in the approved finish schedule.
Fasteners and sealingApproved joints and seals - Corrosion-compatible fasteners, EPDM, butyl or approved sealants: No unsealed field cut is accepted at joints, corners, roof laps or penetrations.

Table 2: insulation, interior, openings, services, options and scope

ComponentDetail
Wall insulationPUF wall thermal core - 50 mm standard planning thickness, 80 mm option, density and thermal data by supplier certificate: Do not infer fire resistance from PUF thickness. A non-combustible core means a tested mineral-wool panel system instead.
Roof insulationPUF or PIR roof thermal core - 60-80 mm planning range, supplier-certified density and thermal data: Thickness is selected for heat gain, span and condensation. Supplier data governs allowable spans and fastener spacing.
Interior wallsFactory-finished inner wall face - Inner PPGI or GI panel facing, no separate MDF lining in the standard build: The panel inner face is the finished wall unless a decorative or hygienic lining is separately ordered.
CeilingInsulated roof underside or optional service ceiling - Exposed inner panel liner, or lightweight service ceiling below: A false ceiling creates a service void. It does not replace the roof panel's thermal function, and vapour control stays continuous.
Main door and service doorInsulated door assembly - PUF-panel or insulated MS door with sealed perimeter: Leaf and frame are selected to reduce thermal bridging and air leakage. Hardware suits transport and repeated use.
Windows and service openingSealed aluminium window assembly - Powder-coated aluminium with 4-5 mm glass or upgraded glazing: Frames are flashed and sealed into the panel with no exposed core. Larger glazing needs a framed structural opening.
Grills and mosquito meshOpening protection - Grill, mesh, guard or louver as scheduled: Provided only where the approved opening schedule and intended use require it.
Electrical wiringCopper wiring and containment - 1.5 / 2.5 / 4 sq.mm copper starting schedule, final by load: Lighting, socket and higher-load or AC circuits, subject to the final load schedule and approved electrical drawing.
Electrical protectionDB, MCB, RCCB and earthing - Segregated protected circuits to approved electrical drawing: Lighting, socket, wet-area and AC circuits are segregated per the approved drawing.
Electrical fittingsLights, sockets and equipment points - LED lights, modular switches, 6A and 16A sockets, fan and AC provision: Final quantities and equipment loads are quotation-specific.
Ventilation and ACCondensation-aware ventilation or AC - Natural ventilation or AC with controlled condensate: AC sleeves and drains are factory planned so insulation and vapour sealing are restored around penetrations.
Plumbing and sanitaryOptional plumbing in insulated panels - Factory-planned sleeves and chases, penetrations sealed, core protected: Pipes are never routed by cutting large unprotected channels through panels. Service zones are planned before manufacture.
Layout and configurationInterlocking insulated-panel cabin - Factory-cut panels, interlocking joints, butyl or approved sealants and flashings: Precision interlocking and joint sealing limit air gaps and thermal bridges. The purchase order identifies the selected panel system.
Painting and coatingCorrosion-protection system - Substrate-appropriate protection and touch-up: Prepared MS takes the approved primer and topcoat. Galvanized or coated steel takes compatible cut-edge repair and touch-up.
Quality checksInspection and testing - Pre-dispatch dimensional, enclosure, service and functional QA: Covers dimensions, panel identification, connections, coating, drainage, weather sealing, doors, windows and electrical continuity.
WarrantyCommercially confirmed warranty - Final quotation governs scope and exclusions: 5-year structural and 1-year finishing warranty as standard, finishing extendable to 2 years on request, confirmed at quotation.
Cross-section of a PUF porta cabin showing the MS chassis, floor grid, wall and roof sandwich panels with the steel schedule
Insulated panel construction, cross-section through the 20 x 10 x 8.5 ft reference configuration. Illustrative, not for construction. Drawing SP-PC-PUF-08-DWG-R1.
Detail sheet showing an interlocking wall panel joint, flashed junctions, a sealed service penetration and the envelope specification
Envelope continuity and joint sealing: joints, junctions, penetrations and openings. Illustrative, not for construction. Drawing SP-PC-PUF-08-DWG-R2.

Shipping & Delivery

Delivery information and warranty details

Every SAMAN cabin is delivered factory-direct from our Bengaluru (South) or Greater Noida (North) unit on an open trailer, with delivery and installation across South and North India in 7–21 working days. Cabins up to 20 ft travel on a 20 ft open trailer; 30 ft and 40 ft cabins travel on a 40 ft open trailer. Unloading by crane or manual placement is arranged based on your site access and confirmed at quotation.

Free delivery: within Bangalore city (South zone) · Delhi NCR: Ghaziabad, Gurugram, Faridabad, Noida and Greater Noida (North zone).

20 ft open trailer · freight by distance (both zones)

DistanceFreight (Rs)
100–150 km25,000–30,000
150–200 km30,000–35,000
200–250 km35,000–40,000
250–300 km40,000–45,000
300–350 km45,000–50,000
350–400 km50,000–55,000
400–450 km55,000–60,000
450–500 km60,000–65,000
500–550 km65,000–70,000
550–600 km70,000–75,000
600–650 km75,000–80,000
650–700 km80,000–85,000
700–750 km85,000–90,000
750–800 km90,000–95,000
800–850 km95,000–100,000
850–900 km100,000–105,000
900–950 km105,000–110,000
950–1,000 km110,000–115,000

40 ft open trailer · freight by distance (both zones)

DistanceFreight (Rs)
100–150 km30,000–35,000
150–200 km35,000–40,000
200–250 km40,000–45,000
250–300 km45,000–50,000
300–350 km50,000–55,000
350–400 km55,000–60,000
400–450 km60,000–65,000
450–500 km65,000–70,000
500–550 km70,000–75,000
550–600 km75,000–80,000
600–650 km80,000–85,000
650–700 km85,000–90,000
700–750 km90,000–95,000
750–800 km95,000–100,000
800–850 km100,000–105,000
850–900 km110,000–115,000
900–950 km115,000–120,000
950–1,000 km120,000–125,000

The 40x10 size moves on a 40 ft trailer and reads from the 40 ft freight band.

Typical destinations from our Bengaluru unit (South zone)

approximate road distance, find your freight band in the tables above; final charge confirmed at quotation

CityApprox. distanceFreight band
Mysuru~145 km100–150 km
Salem~215 km200–250 km
Tirupati~250 km250–300 km
Mangaluru~350 km300–350 km
Chennai~350 km300–350 km
Coimbatore~365 km350–400 km
Hubballi~410 km400–450 km
Madurai~435 km400–450 km
Kochi~550 km500–550 km
Goa (Panaji)~560 km550–600 km
Hyderabad~570 km550–600 km
Vijayawada~630 km600–650 km

Typical destinations from our Greater Noida unit (North zone)

approximate road distance, find your freight band in the tables above; final charge confirmed at quotation

CityApprox. distanceFreight band
Agra~165 km150–200 km
Haridwar~230 km200–250 km
Jaipur~255 km250–300 km
Dehradun~285 km250–300 km
Chandigarh~290 km250–300 km
Gwalior~330 km300–350 km
Ludhiana~390 km350–400 km
Kanpur~440 km400–450 km
Lucknow~470 km450–500 km
Amritsar~490 km450–500 km
Bhopal~600 km550–600 km
Varanasi~760 km750–800 km

Distances beyond 1,000 km are quoted at booking. ODC (over-dimensional cargo) charges depend on the state. All freight figures are tentative, the final charge is confirmed once your delivery location and order are confirmed, and may vary slightly with the route and return-vehicle availability.

Warranty & Support

5-year structural warranty and 1-year finishing warranty as standard; finishing warranty extendable to 2 years on request, confirmed at quotation. Warranty scope and exclusions are confirmed in the final quotation, and misuse, site services, consumables and unapproved alterations remain outside the agreed scope unless explicitly included. Base specification price: customisations quoted separately. After-sales support and spare parts available from our Bengaluru and Greater Noida units.

Customer Reviews

0 reviews

No reviews yet. Be the first to review this product.

Write a Review for PUF Porta Cabin

Your email is not published.

Reviews are published after approval by our team.

Built by a verified manufacturer: ISO 9001:2015 certified, Udyam registered, NSIC-enlisted, GST registered.

View manufacturer credentials