Multi-Story Container Office: Six Approved G+1 Sizes

Choose your size - six factory-built options

20x8 ft G+1 Multi-Story Container Office

₹4,71,200 + GST

₹5,56,016 incl. 18% GST

A multi-story container office stacks two fitted container office floors into one G plus one building. SAMAN supplies six approved footprints, from 20 x 8 ft to 40 x 32 ft. Together they give 320 to 2,560 sq ft of gross floor area across both levels. The ground and first floors repeat the same approved plan, so openings, partitions, workstations and services line up one above the other. Every layout carries its external doors on one long wall, keeps both end walls door free, and reaches the upper floor by an outside deck and stair. Stacking, connections, foundations and erection stay under project engineering, and we price the building from its approved gross area.

Size
20 x 8 ft per floor, G+1
Gross floor area
320 sq ft over two levels
Price from
Rs 4,71,200 ex GST
Workstations
6 across both floors
Upper floor access
Wall A deck, external stair at the End D corner

Custom sizes available · 500+ projects delivered · Factory-tested before dispatch

Product Information

Download the G+1 technical specification and GA set

When Stacking Beats Spreading Out on a Crowded Project Site

Most site offices grow sideways. A G plus one building grows upward instead, so the same team sits on half the ground area. That matters on a tight compound. It matters again when material stacks fill the plot, or when the office must stay clear of the working face. Two levels also sort the roles out. Site staff work at ground level near the gate. Planning, billing and client meetings move upstairs, away from the boots and the noise.

The trade is engineering. A single cabin sits on levelled ground and asks for little else. A stacked building needs a designed foundation, a checked column line and a signed connection detail. Your civil contractor receives point loads rather than one simple base rail. If your site cannot carry that, the single-storey options in the full container office range will reach you sooner. They also cost less for each square foot you buy.

Send us your plot size, head count and ground conditions for a G plus one quote
Two level container office on a prepared yard with the Wall A access deck and external stair in view

Read the engineering boundary before you fix a size

Six approved sizes are drawn, priced and ready to quote. The building around them still needs a designed foundation, a signed connection detail and an erection plan.

That work sits outside our published rate, and we would rather show you the line now than move it later. Send the plot, the ground conditions and the head count, and we will tell you what has to be engineered.

Ask us what your ground has to carry
Approved G+1 GA board for the 20 x 8 ft multi-story container office, both floor plans

20 x 8 ft G+1: 320 sq ft From a 160 sq ft Footprint

This is the smallest approved stack and the one that saves the most ground. Each floor is a single open office of 160 sq ft with three workstations along Wall B and three ceiling cabinets above them. A clear centre aisle runs the length, and both end bays stay free of furniture. One door per floor sits mid way along Wall A, with a window each side of it. Pick it when the gate area is small and six desks are enough.

  • Rs 4,71,200 ex GST, Rs 5,56,016 with 18 per cent GST
  • 160 sq ft per floor, 320 sq ft gross, two stacked 8 ft bands
  • 6 windows and 1 external door per floor, both end walls solid
  • 3 workstations per floor, 6 in total, 6 ceiling cabinets
  • Clear centre aisle, with both end bays kept free of furniture
20 x 8 ft G+1320 sq ft₹4,71,200 + GST1,472.50/sq ft

20x8 ft G+1 Multi-Story Container Office

₹4,71,200 + GST

SAMAN multi-story container office calculator
SAMAN Portable

PRICE IT YOURSELF

Your Multi-Story Container Office from ₹4,71,200

Set the size, choose the finish, watch the price move as you go.

Start your design

Fixed-price quote within 48 hours. Built in our own works.

Customized cabin

Multi-Story Container Office

20×10 ft · 200 sq ft

Estimated total

₹2,10,980₹2,48,956 incl. GST

Step 1 of 9

Choose your product

Pick the building closest to what you need. You can change it at any point.

Choose your product

Set the size

Area and price update as you type. Every size prices from our base-cabin rate card; the larger the floor area, the lower the rate per square foot.

Enter a length and width between 4 and 60 ft. For larger buildings, request a quotation and we will size it with you.

Rooms and partitions
Partition doors
Drawing view
D1W1W220' 0"10' 0"2D Plan

R = room · D = door · W = window

On the drawing, R1 is Room 1, D1 is Door 1 and W1 is Window 1. Every control and every line of your quotation uses the full words.

Carpet Area200 sq ft
Base cabin price₹2,00,000
Roof
Mobility

Enter any size you need. All sizes price from the same base-cabin rate card, and your figure is confirmed on the drawing.

Frame and wall

Choose what the cabin is built from. The frame carries the load, the wall closes it, and both move the price.

Structural frame
Wall construction

Choose the interior

Standard finishes are included. Upgrades and savings are shown per square foot.

Internal wall lining, per sq ft of wall
Ceiling, per sq ft of floor
Flooring, per sq ft of floor
Wall build-up from outside to inside
Weather skin50
Structural faceMS frame & panel support
Thermal layer50 PUF
Added insulation, per sq ft of wall and ceiling

Add doors and windows

Set the type, the count and where each one sits. The plan updates as you choose.

Door placement

Door 1
Hinge side
Opening
Use "In" when hand flow should remain inside the room edge. Use "Out" when swing clearance is outside.

Window placement

Window 1
Track
Track choice affects how much frame is needed along the edge.
Window 2
Track
Track choice affects how much frame is needed along the edge.

If the entrance sits under a shed or a covered walkway, choose opens in, so rain does not blow through the doorway. On an open site choose opens out, because the door seals tighter against wind. Hinge left and hinge right set which side the handle falls on.

A 2.5 track slides more smoothly and costs more than a 2 track. The difference scales with the size of the window.

Drawing view
D1W1W220' 0"10' 0"2D Plan

R = room · D = door · W = window

On the drawing, R1 is Room 1, D1 is Door 1 and W1 is Window 1. Every control and every line of your quotation uses the full words.

Carpet Area200 sq ft
Base cabin price₹2,00,000

Add electrical fittings

Tick what you need. Quantities are suggested from the floor area and you can change every one.

Light colour
LED shape
Socket placement, no cost impact

Placement moves a socket, it does not add one. The charge is the plug point count above, and moving a socket costs nothing.

Front
Rear
Left
Right
Drawing view
D1W1W220' 0"10' 0"2D Plan

R = room · D = door · W = window

On the drawing, R1 is Room 1, D1 is Door 1 and W1 is Window 1. Every control and every line of your quotation uses the full words.

Carpet Area200 sq ft
Base cabin price₹2,00,000

Add furniture and fittings

Everything here is optional. Add only what you want fitted before delivery.

Some fit-out components are being confirmed and show as Quoted separately.

Furniture position

Delivery and taxes

Transport and installation are optional and depend on your site. GST is shown as its own line.

Delivery scope
See the full distance ladder
Delivery freight ladder, ex-GST
Distance20 ft trailer40 ft trailer
Bangalore cityFreeFree
Delhi NCRFreeFree
Under 100 kmConfirmed at quotationConfirmed at quotation
100-150 km₹27,500₹32,500
150-200 km₹32,500₹37,500
200-250 km₹37,500₹42,500
250-300 km₹42,500₹47,500
300-350 km₹47,500₹52,500
350-400 km₹52,500₹57,500
400-450 km₹57,500₹62,500
450-500 km₹62,500₹67,500
500-550 km₹67,500₹72,500
550-600 km₹72,500₹77,500
600-650 km₹77,500₹82,500
650-700 km₹82,500₹87,500
700-750 km₹87,500₹92,500
750-800 km₹92,500₹97,500
800-850 km₹97,500₹1,02,500
850-900 km₹1,02,500₹1,07,500
900-950 km₹1,07,500₹1,12,500
950-1000 km₹1,12,500₹1,17,500

Delivery in 7 to 21 working days. Freight is confirmed once the exact delivery location and order are approved.

Get your quotation

Send us this configuration and we will confirm it with a fixed price within 48 hours.

Submit the exact configuration for a fixed, itemised quotation within 48 hours.

Your contact detailsEnter a 10-digit Indian mobile number.Please add your email so we can send your quotation PDF.

Please add your name and mobile number so our sales team can send your fixed quotation.

Published cabin price tables

All primary prices are ex-GST. Including-GST figures apply 18 percent GST.

Container Office price table
Container Office published size and price ladder
SizeAreaPrice ex-GSTIncluding 18% GST
20x8 ft G+1320 sq ft₹4,71,200₹5,56,016
20x16 ft G+1640 sq ft₹9,12,640₹10,76,915
40x8 ft G+1640 sq ft₹9,12,640₹10,76,915
40x16 ft G+11,280 sq ft₹17,85,600₹21,07,008
40x24 ft G+11,920 sq ft₹26,78,400₹31,60,512
40x32 ft G+12,560 sq ft₹35,71,200₹42,14,016
Indicative estimate SP-EST · 01 Sept 2026 · Fixed, itemised quotation within 48 hours of submission.

You may also like

Other container office configurations in the same range.

Product Details

Comprehensive information about Multi-Story Container Office

Product Overview

Detailed information about Multi-Story Container Office

What a multi-story container office actually is

Multi-story container office in a works yard, two levels with a Wall A deck and external stair

A multi-story container office is one building. It carries two fitted container office floors, one set directly on the other. SAMAN calls this a G plus one, and the approved family runs to six footprints. Every option repeats the same room plan, opening schedule, furniture layout and service route on both levels. Nothing shifts between the ground floor and the first floor.

That repetition is deliberate. It keeps the structure predictable, and it keeps the drawings short. When a room, a door or a riser sits in the same place on both levels, loads travel straight down a known line. It also means a buyer only has to understand one floor plan to understand the whole building.

The approved footprints are 20 x 8 ft, 20 x 16 ft and 40 x 8 ft. The three widest are 40 x 16 ft, 40 x 24 ft and 40 x 32 ft. Because each carries two occupied levels, the gross floor area runs from 320 sq ft to 2,560 sq ft. Floor to floor height is 8 ft 6 in nominal. The plans sit on 8 ft bands that line up through both levels.

Why a second floor changes the engineering, not just the area

A single-storey cabin only has to hold itself up and stay square when a crane lifts it. Stack a second one on top and three new questions appear at once. Where do the upper loads come down? What holds the two modules together? And what does the ground have to carry at each of those points?

The lower module gets a stack engineered chassis. We design its perimeter for the reactions of the storey above and for the support points below. Cross members and local plates gather load at the stack columns, at the stair landings and along the joining lines. A single-storey frame is never assumed fit for stacking without a signed design.

The stack column line

Column continuity is what makes the stack work. Heavy posts run as a continuous line from the top rail down to the foundation. Large openings get extra reinforcement, or a moment frame around them. The building does not count as stackable until we issue the calculations and the connection details.

The inter-module lock

The two modules meet at the top frame of the lower unit. Engineered top rails carry column caps and either twist lock or bolted stack plates, and those plates are shop fitted and uniquely identified. The connection transfers vertical load, shear and uplift on its own. It never leans on the facade panels to do that work.

Weather sealing is a second, separate system at the same joint. Gaskets, flashings, fire stops and closure panels close the line after the structure is bolted up. Both systems get inspected after erection, and again after any relocation.

What the foundation has to carry

Foundation reactions are the part most buyers underestimate. The load no longer spreads evenly along a base rail. It concentrates at the stack column positions, at the stair base and at the landing supports. Your civil contractor needs those point loads before pouring anything, and the design of the foundation stays a project engineering item outside our published rate.

How to read the approved GA before you fix a size

Compact G+1 container office on paving, one door and two windows per floor on the access wall

Each of the six sizes has an approved GA board, and the technical PDF carries all six plus twelve size specific drawings. Read three things on the board before you fix a size. Read the per floor opening ledger, the repeated floor program and the access note.

The opening ledger lists every door, window and service louvre by wall, with its position in feet along that wall. Wall A is the access and door wall on every size. Both end walls carry zero external doors. On the four wider sizes, the service end is solid apart from two high level louvres per floor.

The floor program tells you what actually sits on the floor. It gives workstation counts, room names and room sizes. Each approved workstation is about 4 x 2.5 ft and has one matching ceiling attached cabinet above it. If your team needs more desks than the program shows, move up a size rather than crowding the plan.

Choosing between the six approved sizes

Island of workstations on a multi-story container office floor with ceiling cabinets above

Two of the six sizes give exactly 640 sq ft of gross area, and they cost the same. The 20 x 16 ft option puts that area into a wide, serviced floor with a pantry and toilets on each level. The 40 x 8 ft option lays it out long and narrow. It gives a manager room at one end and seven desks in a single run. Width buys rooms. Length buys desk positions.

The two smallest options suit a gate office or a compact project office. The 20 x 8 ft plan holds three desks per floor and nothing else. The 20 x 16 ft plan is the first one where each floor can run alone. Its pantry, toilets and wash repeat on both levels.

The three widest options are project headquarters, not site cabins. The 40 x 16 ft plan adds a conference room beside the manager room. The 40 x 24 ft plan brings a reception and a six desk island. The 40 x 32 ft plan carries four front rooms, twenty desks per floor and four support rooms.

The six approved G+1 options at a glance
Footprint per floorGross sq ftWorkstations G+1Windows per floorExternal doors per floorPrice ex GST
20 x 8 ft320661Rs 4,71,200
20 x 16 ft640851Rs 9,12,640
40 x 8 ft6401492Rs 9,12,640
40 x 16 ft1,2801492Rs 17,85,600
40 x 24 ft1,92028102Rs 26,78,400
40 x 32 ft2,56040112Rs 35,71,200

Getting to the first floor, and out again

Access is external on every approved option. A first floor deck runs outside Wall A, and a steel stair rises to it at the Wall A and End D corner. Keeping the stair outside protects floor area, because an internal stair would eat a workstation bay on both levels.

The GA shows the deck and the stair as coordination envelopes. Project engineering sets the final rise and run, the landing size and the guardrail design. It also sets the fire strategy and the escape provisions, against your occupancy and your local rules. We do not publish a stair specification, because the right one depends on your site.

Upper floor openings carry their own safety items. Glazing on the first floor allows for wind, guarding and safe cleaning access. Where an opening needs it, the approved schedule adds guards, restrictors or mesh. On the upper level those are structural safety items and not decorative extras.

How the two-level module is built

The exterior is a clean corrugated steel container office skin with a flat ISO roof and container corner castings. Only the top storey carries the finished roof system. The roof of the lower module becomes an interstitial floor interface. It therefore needs coordinated waterproofing and fire detailing, not a normal roof build up.

Wall panels are steel skinned or insulated panels, with engineered joints, cavity barriers and framed openings. The joints allow for movement between storeys and stay reachable for site sealing. Wall insulation is typically 50 to 100 mm of mineral wool, PUF or PIR, chosen against the fire strategy and the climate. The top roof usually takes about 100 mm of mineral wool or an engineered sandwich roof.

Floors are built for office live load, partition load and vibration, and they also act as a diaphragm between modules. The deck is marine plywood, Bison panel or cement fibre board on engineered joists, with wet and high load zones upgraded. Upper floor decks take extra impact, acoustic and fire detailing at the underside and at the module joints.

Interior linings are gypsum, fibre cement or laminated plywood. Stair enclosures, escape routes, electrical rooms and inter module boundaries take the fire and acoustic performance the code and the project brief call for. Floor finishes are SPC, LVT or vinyl, with metal or flexible transitions across the module joins so the joint can be opened again later.

Services that have to run between two floors

Service bay inside a multi-story container office with pantry, toilet doors and a wash counter

A stacked building needs vertical service routes, and those are planned before fabrication. Electrical circuits run horizontally in segregated containment on each floor and rise through protected risers between them. Each module has identified connection points, so the site joints are controlled and testable, and fire stopping is made good after the riser goes in.

Protection is coordinated for the whole G plus one building rather than for two separate cabins. That means a main incomer, floor distribution boards, MCB or RCBO and RCCB protection, surge protection where required, and bonded module frames. Stairs, landings and escape routes stay lit during the defined emergency condition.

Cooling is zoned by room and by floor, using split, VRF or ducted systems. Outdoor unit frames and vertical condensate routes are engineered with the facade, the stair and the roof equipment in mind. Where toilets or a pantry are included, the wet cores are stacked in line so there are fewer joints and less leakage risk.

What the published rate covers, and what it does not

Manager room inside a multi-story container office with a desk, visitor chairs and a window

The published rate covers the fabricated and fitted modules as the approved GA describes them. We calculate it on gross floor area across both levels. The base is Rs 1,550 per gross sq ft at the reference band, adjusted by the retained size band multiplier. The 801 sq ft and above band applies to the three widest options.

Several things sit outside that rate, and we would rather say so on the page than in a revised quotation. Foundations and geotechnical work are excluded. External stairs, landings and guardrails are excluded. Craneage, site erection, structural calculations and statutory approvals are excluded. Interior fit out beyond the approved schedule and sanitary fit out are excluded unless the quotation lists them.

Prices on this page are ex GST and exclusive of freight. GST is shown at 18 per cent for reference. The final quotation separates the shell, the connections and the site erection. It also separates the waterproofing, the stairs, the MEP work and the finishes. You can then see which part of the number belongs to which scope.

Getting the site ready before the first module arrives

Ground preparation matters more here than for a single cabin. The site needs a level, engineered support at every stack column position, at the stair base and under the landing. Those positions come from the foundation reaction drawing, which is issued as part of project engineering once the size and the site are fixed.

You also need working space around the building. The crane needs a hardstanding and a swing radius. The stair needs a clear approach. The deck needs a route that stays usable through the monsoon. Others bring utilities up to a connection point. We coordinate drainage so that roof water never runs onto the stairs or the module joints.

Craneage, transport and the erection sequence

The modules travel separately and are lifted in their approved shipped condition. Each one has certified lifting points, a tagged centre of gravity and an erection sequence. Erection covers temporary stability, alignment, connection, weather sealing and the release of the lifting restraints, in that order.

Acceptance happens after site assembly rather than at factory dispatch. We run a module test at the works. On site we then check connection fit up, bolt torque, plumbness and level. We also check joint sealing, electrical continuity and the egress route. Coating gets inspected again after erection, because stack joints, lifting and site welding all mark factory paint.

Where this sits against our other container offices

If your plot allows the same team to spread out on one level, a stacked building is the wrong answer. It costs more per square foot and it brings engineering that a single cabin does not need. Our fabricated single-storey line, the container office cabin, is the cheaper way to buy floor area when ground is not scarce.

If the office is for one project team on an active construction site, look at the site office container instead. It is built around site duty, relocation and a project office layout. Some buyers want a converted freight shell, with its ISO form and cargo door kept. That is the shipping container office rather than this page.

This page exists for one decision only. You need two levels on one footprint, and you accept the engineering that comes with it. Everything else in the cluster is single storey.

What to send us so we can quote well

Send us the plot dimensions and a site plan marked with the crane approach. Tell us the head count you need on each floor, and whether toilets and a pantry must be on both levels. Give us the ground conditions or a soil report if you have one, and the local approval route you expect to follow.

Add your power supply point, the AC preference and the finish level you want inside. With those in hand we can size the building and price it against the approved ladder. We can also set out what project engineering must deliver before fabrication starts.

Questions buyers ask about G+1 container offices

Can a SAMAN single-storey container office be stacked later?

No. A single-storey frame is not assumed suitable for stacking. A G plus one building uses a stack engineered lower chassis, a continuous column line and designed connections, and none of that can be added to a cabin after the event.

Does the price include the foundation and the stair?

No. The published rate covers the fabricated and fitted modules only. Foundations, geotechnical work, external stairs, landings, guardrails, craneage, site erection, structural calculations and statutory approvals are quoted separately.

Why is the first floor reached from outside?

An external deck and stair keep both floor plates whole. An internal stair would take a workstation bay out of each level, and on the smaller options that is a large share of the floor.

Can I have a door in the end wall?

No. Every approved option carries its external doors on Wall A, and both end walls stay solid. That rule protects the column line and the escape route logic on both floors.

Why do the 20 x 16 ft and 40 x 8 ft options cost the same?

Both give 640 sq ft of gross floor area, and the rate is set per gross square foot within a size band. What differs is the plan. One buys rooms and services, the other buys desk positions along a longer wall.

How many people can work in a multi-story container office?

The approved programs run from six workstations in total on the 20 x 8 ft option to forty on the 40 x 32 ft option. Seat counts beyond the program are not approved, because each workstation has a matching ceiling cabinet and a planned service position.

Can the building be relocated after it is erected?

It can be dismantled and moved, but relocation needs a renewed structural and connection review. Both the structural bolts and the weather seals are inspected again after any move.

Technical Specifications

Detailed technical information and features

Read this the way an engineer reads it. Almost every line below changes because there is a floor above, and the difference is written into the right hand column. Final member sizes, materials and performance stay controlled by the signed quotation, the approved shop drawings and project engineering.

Structure, envelope, roof and floor

Structure, envelope, roof and floor
ComponentWhat SAMAN suppliesWhat the second floor changes
Bottom frameStack engineered lower module chassis in heavy MS or HSLA perimeter sectionSized for upper storey column reactions and foundation support points, not for one floor
Bottom stiffenersFloor diaphragm and support grid in heavy channel or RHS, with local platesPlates gather load at stack columns, stair landings and joining lines
Floor frameOccupied floor and inter storey diaphragmChecked for office live load, partition load, vibration and module to module continuity
Top frameUpper perimeter and stack interface with column caps and stack platesTwist lock or bolted plates transfer vertical load, shear and uplift without the facade
Roof stiffenersRafters and purlins for the top storey roof and service frameOnly the top storey carries the roof system; the lower roof becomes a floor interface
Corner posts and wall linesPrimary stack columns with braced wall lines and opening reinforcementColumn continuity and the lateral system are project specific and require signed calculations
Lifting and handlingCertified lifting points, temporary bracing, tagged centre of gravityEach module is lifted in its approved shipped condition to a set erection sequence
Welding and fabricationApproved WPS, bolt grades and torque, weld inspection, dimensional surveyCritical stack connections and lifting points receive documented inspection
Exterior wallsSteel skinned or 50 to 75 mm insulated panels with engineered jointsJoints allow inter storey movement and stay accessible for site sealing
RoofInsulated profiled roof or panel system with positive fall, gutters and flashingsDrainage is coordinated so water never discharges onto stairs, entrances or module joints
Wall insulation50 to 100 mm mineral wool, PUF or PIR by fire strategy and climateInsulation runs continuous across module joins and around columns, with cavity barriers
Roof insulationTypically 100 mm mineral wool or an engineered sandwich roofApplied over the assembled building where needed, to close thermal breaks at joints
Floor baseMarine plywood, Bison panel or cement fibre deck on engineered joistsUpper floors add impact, acoustic and fire detailing at the underside and at joints
Floor finishSPC, LVT, vinyl or a project selected finish with movement transitionsTransitions cross module joins so connections can be reopened later
Interior wallsGypsum, fibre cement, laminated plywood or tested fire rated assembliesStair enclosures, escape routes and inter module boundaries take rated performance
CeilingGypsum, mineral fibre or laminated ceiling with access to MEP routesCeiling zones carry horizontal services and the vertical risers between floors
External finishPaint, ACP, HPL, fins, canopy and signage on an engineered subframeFeatures must not create climbing points or block rescue access at first floor level
Fasteners and sealingStructural bolts to grade and torque, EPDM or butyl seals, flashings, fire stopsStructure and weather sealing are separate systems, both inspected after erection
Opening ledger and repeated floor plan for the 40 x 16 ft G+1 container office option
Opening ledger and repeated floor plan, 40 x 16 ft option MSCO-40X16-G1-CORPORATE-V1. User approved architectural GA V1, 24 August 2026. Illustrative, not for construction. Each of the six approved sizes has its own board inside the technical PDF.

Openings, services, options and site scope

Openings, services, options and site scope
ComponentWhat SAMAN suppliesWhat the second floor changes
Main and service doorsInsulated or fire rated doors with closers, panic hardware where requiredDoor swing, travel distance and escape width are checked against occupancy on both floors
Windows and service openingsPowder coated aluminium or steel windows with safety glassUpper level glazing allows for wind, guarding and maintenance access
Guards, mesh and louvresGuards, restrictors, insect mesh and weather louvres per the approved scheduleUpper storey guards and restrictors are structural safety items, not accessories
Electrical wiringCopper wiring in segregated containment with flexible inter module connectionsProtected vertical risers link the floors, with fire stopping made good afterwards
Electrical protectionMain incomer, floor distribution boards, MCB or RCBO, RCCB and SPD as requiredCoordination, fault level and earthing are checked for the whole G plus one building
Electrical fittingsLED office lighting, sockets, data, stair lighting, exit and emergency lightsStairs, landings and escape routes stay lit during the defined emergency condition
Ventilation and ACSplit, VRF or ducted systems zoned by room and by floorOutdoor unit frames and vertical condensate routes are engineered with the facade and roof
Plumbing and sanitaryOptional stacked wet services with vented waste and accessible valvesWet cores align vertically to cut joints and leakage risk; base price excludes fit out unless shown
Layout and configurationApproved ground and first floor plans, stair type, landing, corridor and occupancyPricing area is gross floor area over both levels, fixed on the approved GA
Painting and coatingPrepared MS with project coating, shop painted modules plus site repairCoating is inspected again after erection because joints and lifting mark factory paint
Quality checksModule works test, connection fit up, bolt torque, plumbness, level, sealing, electrical testsFinal acceptance happens after site assembly, not at factory dispatch
Warranty and exclusionsWarranty split across shell, connections, erection, waterproofing, stairs, MEP and finishesFoundations, geotechnical work, external stairs, craneage and third party approvals stay excluded
Stacking, access and service coordination section for the 40 x 16 ft G+1 container office
Stacking, access and service coordination envelope, 40 x 16 ft option. User approved architectural GA V1, 24 August 2026. Illustrative, not for construction. Stair, guardrail, egress, foundations and connections require signed project engineering.

Shipping & Delivery

Freight tables and delivery terms

Container offices ship as complete steel modules on open trailers: 20-ft-class sizes on a 20 ft trailer, 40-ft-class and twin modules on a 40 ft trailer, with ODC routing planned for 20×20 and 40×12. Every dispatch includes a crane plan at both ends: the same lugs that lift the unit at our works place it on your pad. Free delivery within Bangalore city and Delhi NCR (Ghaziabad, Gurugram, Faridabad, Noida, Greater Noida). ODC charges are tentative and confirmed with your order and route.

20 ft open trailer · freight by distance (both zones)

DistanceFreight (Rs)
100–150 km25,000–30,000
150–200 km30,000–35,000
200–250 km35,000–40,000
250–300 km40,000–45,000
300–350 km45,000–50,000
350–400 km50,000–55,000
400–450 km55,000–60,000
450–500 km60,000–65,000
500–550 km65,000–70,000
550–600 km70,000–75,000
600–650 km75,000–80,000
650–700 km80,000–85,000
700–750 km85,000–90,000
750–800 km90,000–95,000
800–850 km95,000–100,000
850–900 km100,000–105,000
900–950 km105,000–110,000
950–1,000 km110,000–115,000

40 ft open trailer · freight by distance (both zones)

DistanceFreight (Rs)
100–150 km30,000–35,000
150–200 km35,000–40,000
200–250 km40,000–45,000
250–300 km45,000–50,000
300–350 km50,000–55,000
350–400 km55,000–60,000
400–450 km60,000–65,000
450–500 km65,000–70,000
500–550 km70,000–75,000
550–600 km75,000–80,000
600–650 km80,000–85,000
650–700 km85,000–90,000
700–750 km90,000–95,000
750–800 km95,000–100,000
800–850 km100,000–105,000
850–900 km110,000–115,000
900–950 km115,000–120,000
950–1,000 km120,000–125,000

Typical destinations from our Bengaluru unit (South zone)

approximate road distance, find your freight band in the tables above; final charge confirmed at quotation

CityApprox. distanceFreight band
Mysuru~145 km100–150 km
Salem~215 km200–250 km
Tirupati~250 km250–300 km
Mangaluru~350 km300–350 km
Chennai~350 km300–350 km
Coimbatore~365 km350–400 km
Hubballi~410 km400–450 km
Madurai~435 km400–450 km
Kochi~550 km500–550 km
Goa (Panaji)~560 km550–600 km
Hyderabad~570 km550–600 km
Vijayawada~630 km600–650 km

Typical destinations from our Greater Noida unit (North zone)

approximate road distance, find your freight band in the tables above; final charge confirmed at quotation

CityApprox. distanceFreight band
Agra~165 km150–200 km
Haridwar~230 km200–250 km
Jaipur~255 km250–300 km
Dehradun~285 km250–300 km
Chandigarh~290 km250–300 km
Gwalior~330 km300–350 km
Ludhiana~390 km350–400 km
Kanpur~440 km400–450 km
Lucknow~470 km450–500 km
Amritsar~490 km450–500 km
Bhopal~600 km550–600 km
Varanasi~760 km750–800 km

Distances beyond 1,000 km are quoted at booking. ODC (over-dimensional cargo) charges depend on the state. All freight figures are tentative, the final charge is confirmed once your delivery location and order are confirmed, and may vary slightly with the route and return-vehicle availability.

Customer Reviews

0 reviews

No reviews yet. Be the first to review this product.

Write a Review for Multi-Story Container Office

Your email is not published.

Reviews are published after approval by our team.

Built by a verified manufacturer: ISO 9001:2015 certified, Udyam registered, NSIC-enlisted, GST registered.

View manufacturer credentials